Paint Mix Rooms

Garmat(R) USA Paint Mix Rooms are designed to provide a well illuminated, clean ventilated work area for mixing applications. These units utilize a positive pressure environment to help eliminate contaminated shop air from interfering with the mixing process. The Garmat(R) USA paint mix room is a key element when considering your paint shop requirements. We offer several standard models as wellas custom models to meet the needs that are specific to your body shop. Garmat(R) USA Paint Mix Rooms meet NFPA33 codes for paint storage.

Garmat(R) USA Paint Mix Rooms [ETL REPORT #567495] are designed and are ETL listed as being in compliance with the 1995 NFPA 33 guidelines for paint storage.

MODELS

The exterior dimensions on standard models are- 7'10" x 6'7" through 7'10" x 19' all with double wall construction, includes 2 fans and 2 to 4 4-tube light fixtures depending on size.

CONSTRUCTION Structural components utilize electro galvanized steel. Walls are double panel, solid interlock construction with durable powder coated finish. The door is 3' wide and is located on the front wall. It is sealed by closure in rubber compression gasket and fitted with a tempered safety glass observation window.

LIGHTING Each mixing room is equipped with overhead sealed 4-tube light ID.1ureS utilizing color corrected lighting for accurate color mixing and matching.

VENTILATION Shop air is drawn into the room with a 1000 CFM intake fan, filtered and exhausted with a 900 CFM extract fan ensuring fresh air constantly circulating through the room.

FILTRATION Air intake filters measure 14" x 25" x I" and are a fiberglass furnace filter. The air intake filters are fitted at the roof around the intake fan.

CODE COMPLIANCE: NFPA 33 requires that paint mix rooms be installed to contain any possible spills that may occur. Paint mix rooms cannot be installed within 6 feet of a spray area. NFPA 33 requires that paint mix rooms contain automatic fire suppression equipment. Three hundred (300) U.S. gallons of material (2 gallons per square foot) is the maximum paint storage capacity. When in accordance with the 1995 NFPA 33,6-3.2.1, a mixing room can be closer than 6ft. End user is responsible for installation of the equipment based on local code requirements.